Abstract

In this paper, infrared polarization detection information acquisition technology is proposed, and the polarization characteristics of oil spills are modeled and studied. A set of long-wave infrared polarization detection equipment for oil spills is designed and built, and modeling research on oil spill polarization characteristics is carried out to accurately detect and identify oil spill types and for the faster processing of oil spill events. Oil spill accuracy is increased by defining the polarization maintenance method of the polarization optical system and reducing the polarization measurement error brought on by the imaging system. As a result, a higher than 3% contrast exists between the polarization degree image and the corrected infrared intensity image. Outdoor tests using oil, palm oil, crude oil, gasoline, and diesel oil spill types are carried out in a controlled environment to collect data on the polarization of various oil species. According to the findings, each oil species’ infrared polarization contrast with seawater is typically greater than its infrared intensity contrast. However, the polarization data of saltwater, diesel, and palm oil, which are difficult to identify in intensity data, show a noticeable difference, further proving the viability of utilizing polarization to discern oil spills.