Abstract

We report the results of a long term structural health monitoring (SHM) test campaign performed on a concrete bridge. A one-year test campaign was performed by a portable prototype instrument based on stimulated Brillouin scattering in a single-mode optical fibre. The optical fibre sensor was attached along one arch of the bridge using two types of adhesive for comparison purposes. The attached fibre was able to provide the strain distribution along the structure during the one-year test campaign, with a spatial resolution of 1 m. A crack was revealed and correctly localized by the distributed sensor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.