Abstract
PurposeOlecranon fractures are particularly vulnerable to distraction and subsequent fracture dislocation due to the high tensile forces. Surgical treatment aims at reducing the fracture and restoring the anatomical joint surface condition, as well as neutralizing the strain inhibiting fracture healing. The XS nail® (Intercus GmbH, Bad Blankenberg, Germany), an intramedullary implant exerting compression across the entire fracture surface, unlike plates, leaves a minimal extra-cortical profile, and can be secured with threaded locking wires, thereby retaining the anatomical reduction without displacement or steps within the articular surface, which was often found in tension band wiring. After encouraging initial results, the long-term outcome was assessed. MethodsThis retrospective study evaluated the long-term outcome of patients surgically treated at our trauma center between January 2002 and December 2005 using the XS nail®. Patients over the age of 18 years eligible for the study must have undergone surgery for isolated, recent (less than 14 days) traumatic olecranon fractures, without concomitant injuries to the ipsilateral elbow and forearm. Further exclusion criteria were pseudarthrosis, re-fractures and osteotomy for distal humerus surgery, as well as polytraumatized patients unable to aid in their own recovery. Data were retrospectively gathered by standardised questionnaire and patient records, as well as surgery and anesthesiology reports. Data analysis was performed using Microsoft Office Excel® 2016. ResultsThere were 32 patients, 13 males (mean age 49.0 years) and 19 females (mean age 68.9 years) with 11 Schatzkers type D, 7 each type A and C, 5 type B and 2 type E at an average of 55.2 months, all showing complete consolidation. Of them, 6 patients had a loss of range of motion with more than 10° in the sagittal plane, and only 1 patient exceeded 10° reduction of supination. Twenty-five patients reported being pain-free under all circumstances, and all but 2 patients (93.75%) had returned to their previous activity level. The average disabilities of the arm, shoulder and hand score was 21.15 (range 0–88.3), and the overall Mayo elbow performance index was 91.87, without complications, such as wound infection, neurovascular impairment or premature hardware removal. ConclusionUsing the XS nail® system, all fracture types can be successfully treated and the rate of complications was lower than that treated by standard methods published in current literature. An excellent functional outcome, high range of motion as well as good retention of reduction without soft tissue irritation makes this a very suitable implant for fractures subject to tension.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.