Abstract

IntroductionThe Flixene™ vascular graft (Maquet-Atrium Medical, Hudson, NH) has emerged as a new generation synthetic graft, which allows for early needling for haemodialysis. Most studies have shown satisfactory early results. The aim of this study is to report on long-term outcomes of the Flixene graft over eight years in a cohort of patients.MethodsFrom February 2011 to September 2019, 61 patients had 64 arteriovenous graft fistulas (AVGs) by using the Flixene grafts. The median patient age was 67 years; the male to female ratio was 30:31. Diabetes was the reason for the majority of kidney failures (57%). The configuration of the grafts used was mostly upper arm straight AVG. The primary patency rate, secondary patency rate, and surgical complications were assessed.ResultsIn a median follow-up of three years (interquartile range (IQR): 2 - 6), 36 of the AVGs required a fistulogram. Venous side stenosis was the most common cause of high venous pressure or AVG occlusion in 97%. The one-year primary patency rate was 30%. The secondary patency rate was 94.8%, 83.7%, and 77.7% at one, three, and five years, respectively. The longest functional AVG was observed for up to seven years.ConclusionsThis study has shown satisfactory long-term results of the Flixene graft used for hemodialysis. The Flixene graft could be needled within 72 hours without increased complications, which allows the creation of an AVG under an emergency setting to avoid the placement of a central venous catheter (CVC). This strategy should be advocated in future clinical practice.

Highlights

  • The FlixeneTM vascular graft (Maquet-Atrium Medical, Hudson, NH) has emerged as a new generation synthetic graft, which allows for early needling for haemodialysis

  • This study has shown satisfactory long-term results of the Flixene graft used for hemodialysis

  • The Flixene graft could be needled within 72 hours without increased complications, which allows the creation of an arteriovenous graft fistulas (AVGs) under an emergency setting to avoid the placement of a central venous catheter (CVC)

Read more

Summary

Objectives

The aim of this study is to report on long-term outcomes of the Flixene graft over eight years in a cohort of patients. The aim of this study is to report on the long-term outcomes of the Flixene graft over an eight-year follow-up in our cohort of patients

Methods
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.