Abstract

To report on the topographic and visual outcomes 10 years after corneal cross-linking in patients with progressive keratoconus and corneal ectasia after refractive surgery. Cross-sectional cohort study of an original, prospective, randomized, clinical trial. Patients treated in a single center cornea and refractive surgery practice as part of the U.S. pivotal trials, which led to the Food and Drug Administration approval of corneal cross-linking, were recruited for a 10-year follow-up examination. LogMar lines (LL) of uncorrected visual acuity (UCVA) and best spectacle--corrected visual acuity (BSCVA), maximum keratometry, and thinnest pachymetry were evaluated. In addition, the Belin ABCD progression display was used to determine progression (95% confidence interval) of the anterior curvature, posterior curvature, and corneal thickness of each individual eye included. Nineteen eyes of 13 patients treated with standard cross-linking returned for a 10-year follow-up examination. Mean maximum keratometry changed from 58.2±12.0 diopters (D) to 58.3±10.1 D, thinnest pachymetry changed from 440.6±51.6 µm to 442.3±54.4 μm, UCVA changed from 0.79±0.42 LL to 0.86±0.46 LL, and BSCVA changed from 0.38±0.26 LL to 0.33±0.34 LL, 10 years after cross-linking. Individually, 68.5% of the entire cohort, 81.8% of keratoconus eyes, and 50% of eyes with corneal ectasia remained topographically stable 10 years after standard cross-linking. In the entire cohort, visual acuity and topography remained stable 10 years after cross-linking. Over the long-term, eyes with keratoconus seem to be more stable than those with corneal ectasia.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call