Abstract

Three highway test sections were monitored for friction, texture, and noise properties over a period of 4 years. The monitored highways were constructed from dense-graded asphalt (DGA), stone matrix asphalt (SMA), and porous friction course (PFC) mixes. The PFC was intended to reduce tire–pavement noise. It was found that the PFC and SMA pavements exhibited comparable frictional properties (international friction index and skid number), which were significantly higher than those observed in the DGA section. It also was found that the PFC section was the quietest and that SMA was louder than DGA. In general, all three sections performed well, and no failures were noticed in any of the monitored pavements during the course of this study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.