Abstract
To provide detailed information for bronchial dose estimates, aerosol particle size distributions, and radon gas concentration, measurements were made in six residential homes and three laboratory rooms in different office buildings in the city of Ottawa. In the literature, most particle size distribution measurements are taken with samplers operating for a few days at most. In this study, the particle size samplers collected the samples from 77 to 162 d. The equilibrium factor determined from the long-term measurements ranged from 0.6 to almost 1 with an average of 0.75. Even though radon concentrations were quite different between residential setting and office buildings, the average equilibrium factor was similar in the two different indoor environments. The results suggest that at least in some basements, if they were occupied, the radon dose would be about twice as high as normally estimated from the conventional F(eq) value of 0.4.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.