Abstract

The gas exchange system is computer controlled and is designed to measure and control 14 temperature regulated chambers enclosing spruce twigs for several months with minimum ozone absorption. The system is mounted on sun exposed single year classes of a Norway spruce stand in western Jutland, Denmark. Since July 1994 the temperature control system has been in function. Results show that 95% of the temperature measurements inside the cuvettes are within the range −2 to +3 °C of the ambient temperature. Gas exchange measurements show that the current year shoots have a higher net photosynthesis than the older shoots. The net photosynthesis in current year needles on sunny days is significantly reduced by the 6 h daily 30–40 ppb ozone addition.