Abstract

Vein grafts are used extensively to repair blood vessels. However, when suitable vein segments are unavailable, alternative graft materials must be used. This study tested the suitability of 1 mm diameter polytetrafluoroethylene (PTFE) grafts for small-calibre arterial replacements. Grafts of 4 mm length were inserted microsurgically into the iliac arteries of 26 rats. The grafts were removed between 3 and 22 months postoperatively and examined with light microscopy and scanning and transmission electron microscopy (SEM:TEM). Anastomotic intimal hyperplasia was minimal, consisting of a few smooth muscle cells extending 100-200 microns onto the graft. The rest of the PTFE was covered with endothelium. In a few isolated areas, there was a subendothelial layer of smooth muscle, 2-10 cells thick. The short segments used in this study were highly successful, with an overall long-term patency rate of 80%. These grafts showed no evidence of excessive neo-intimal hyperplasia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.