Abstract

Various levels of infraposition of single-implant restorations have been observed in long-term follow-up studies, but little knowledge is available on the biological mechanism behind this pattern. The primary aim of this study is to report the frequency and severeness of implant infraposition in the anterior single-implant application after 17 to 19 years in function and, secondly, to try to relate these observations to anatomical appearance of the shape of the face of the patient. The present study comprised of 57 patients who were provided with 65 CeraOne™ single-tooth restorations (Nobel Biocare AB, Gothenburg, Sweden) between 1989 and 1991. Altogether 46 of these patients were treated with single implants in the anterior region. Besides clinical and radiographic data, clinical photographs, study casts, and patient's assessment of the long-term aesthetic result (visual analog scale) was collected at the termination of the present study. The degree of implant crown infraposition was related to assessed facial shape and to patient and clinical assessment of the aesthetic result by means of Pearson's correlation test. To increase the numbers of patients, another group of 25 patients presented in another similar study were pooled with the present material for prevalence calculations. Altogether 47 patients showed up for the final examination after an average of 18 years (82%). Two implants failed (18 years cumulative survival rates [CSR]- 96.8%) and eight original single-crown restorations were replaced (CSR 83.8%). Three of the replaced crowns were replaced because of infraposition of the crowns. About 40% of the patients showed signs of infraposition, similar in younger and older age groups, but more frequently observed in female patients at termination of the study (p < 0.05). There was a weak trend indicating an association between "long-face" appearance and infraposition of the crown restoration (p > 0.05), and patients were more satisfied with the aesthetic clinical result than the participating clinicians (p < 0.05). Single-implant restorations in the anterior upper jaw may present small degrees of infraposition in long-term perspectives. Female patients seem to be at a higher risk of infraposition (p < 0.05), but no clear relationship between age at implant placement or facial shape and degree of infraposition was possible to establish (p > 0.05). Patients were more satisfied with the aesthetic result, as compared with the clinicians (p < 0.05), and patients seemed to pay less attention to the degree of infraposition in their aesthetic assessments, as compared with most of the clinicians.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.