Abstract

We report the outcome of hydrogel intracorneal lens implantation in 2 patients. The lenses were implanted at approximately 50% depth in the cornea to correct high hyperopic refractive errors of 10.5 diopters (D) and 14.0 D, respectively. Both patients were contact lens intolerant and not suitable for intraocular lens implantation. Surgery was performed in 1988, and the patients were followed until early 2010. The patients showed good tolerance for the intracorneal lenses, but both developed opacities around the implant, leading to reduced visual acuity in 1 patient. Long-term patient monitoring is essential since corneal opacities can develop after many years. Removing the implant is not necessary as the lens can easily be rinsed by lifting the corneal cap.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.