Abstract
Fouling remains a major issue for all membrane applications. This study investigated anti-fouling applications for a side-stream membrane bioreactor (MBR) fed with glucose-based synthetic wastewater. Air sparging, backflushing and high cross flow velocity (CFV) were investigated as anti-fouling strategies. For better comparison of longer test runs, an equation to model effects of MLSS and temperature on viscosity was developed. This study showed that for backflushing with a CFV of 5.2 m/s, the permeability is about 3 times higher than for air sparging with CFV of 2 m/s. Long-term investigations of combined air sparging and backflushing compared to conventional membrane filtration at equal CFVs of 2 m/s showed 4 times higher permeability. The long-term permeability decline can be estimated by a power function of the type P= a t n whereby the factor a is related to the initial permeability and the parameter n indicates how rapidly the flux declines. In most cases it was possible to predict the long term flux decline (over a one week or 8 week period) from data for the first two days of filtration with errors of less than 10%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.