Abstract

A novel approach to chloride ion monitoring in aqueous solutions using a long period grating (LPG) pair is reported, with the LPG pair used (LPGP) comprising two 2.5dB single LPGs and a physical centre-to-centre separation of around 30mm. An ultra-violet excimer laser was used to create the pair through a 250μm amplitude mask. The refractive index change due to the presence of the chloride ion (from an aqueous NaCl solution) was monitored, with the sensor having previously been calibrated using solutions of known refractive indices (RIs). A cross-comparison with the response of a single LPG (LPG1) under similar testing conditions was also carried out, and the results have shown that the LPGP could measure a RI change of ±0.003, achieving an improvement in the precision obtained (by ∼ 6 times) using a single LPG. The focus of the work is on the underpinning technology for early stage corrosion monitoring (and indeed prevention) in structures, arising due to salt and water ingress.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.