In a recent article about pulse pressure variation (PPV), after 4 pages of physiologic explanations, Dr Sondergaard finally concluded that 'the subject is an exceptional demonstration of physiology but hardly guides the management of critically ill patients’ [1]. If I agree with the first part of this statement (I and others spent years dissecting the complex physiology behind PPV), I strongly disagree with the second part of the sentence for three reasons, which are not opinions but facts. First, PPV and stroke volume variation (SVV) are increasingly used to guide fluid therapy both in the operating theater and in ICUs. This was confirmed by published peer-reviewed surveys, showing that the use of dynamic parameters increased from 1% in 1998 [2] to 45% in 2012 [3]. If dynamic parameters were not clinically useful one can doubt clinicians would have embraced this concept as they did. Second, PPV and SVV are today displayed on almost all bedside and hemodynamic monitors, next to other vital signs such as the heart rate, blood pressure and arterial oxygen saturation. If medical device industry has financial interests in doing this, it is not fool enough to make research and development investments on something caregivers do not value in their clinical practice. Third, at least 10 randomized controlled trials have demonstrated that hemodynamic strategies based on PPV or SVV monitoring allow a significant reduction in post-surgical complications and hospital length of stay (Table 1). Table 1 Randomized controlled trials demonstrating the ability of hemodynamic strategies based on pulse pressure variation or stroke volume variation monitoring to improve postsurgical outcome So dynamic parameters are well alive and useful for improving patient outcome. Long live dynamic parameters! Abbreviations PPV: Pulse pressure variation; SVV: Stroke volume variation. Competing interests FM is a Vice-President, Global Medical Strategy, at Edwards Lifesciences. Of note, the above statements do not support the use of any specific medical device.

Highlights

  • pulse pressure variation (PPV) and stroke volume variation (SVV) are increasingly used to guide fluid therapy both in the operating theater and in ICUs

  • PPV and SVV are today displayed on almost all bedside and hemodynamic monitors, next to other vital signs such as the heart rate, blood pressure and arterial oxygen saturation

  • If medical device industry has financial interests in doing this, it is not fool enough to make research and development investments on something caregivers do not value in their clinical practice

Read more

Summary

Introduction

PPV and stroke volume variation (SVV) are increasingly used to guide fluid therapy both in the operating theater and in ICUs. PPV and SVV are today displayed on almost all bedside and hemodynamic monitors, next to other vital signs such as the heart rate, blood pressure and arterial oxygen saturation. If medical device industry has financial interests in doing this, it is not fool enough to make research and development investments on something caregivers do not value in their clinical practice.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.