Abstract
Background/AimLondon Protocol (LP) and Classification allied to high-resolution manometry (HRM) technological evolution has updated and enhanced the diagnostic armamentarium in anorectal disorders. This study aims to evaluate LP reproducibility under water-perfused HRM, provide normal data and new parameters based on 3D and healthy comparison studies under perfusional HRM.MethodsFifty healthy (25 F) underwent water-perfused 36 channel HRM based on LP at resting, squeeze, cough, push, and rectal sensory. Additional 3D manometric parameters were: pressure-volume (PV) 104mmHg2.cm (resting, short and long squeeze, cough); highest and lowest pressure asymmetry (resting, short squeeze, and cough). Complementary parameters (CP) were: resting (mean pressure, functional anal canal length); short squeeze (mean and maximum absolute squeeze pressure), endurance (fatigue rate, fatigue rate index, capacity to sustain); cough (anorectal gradient pressure); push (rectum-anal gradient pressure, anal canal relaxation percent); recto-anal inhibitory reflex (anal canal relaxation percent).ResultsNo difference to genders: resting (LP, CP, and 3D); short squeeze (highest pressure asymmetry); endurance (CP); cough (CP, highest and lowest pressure asymmetry); push (gradient pressure); rectal sensory. Higher pressure in men: short squeeze (maximum incremental, absolute, and mean pressure, PV, lowest pressure asymmetry); long squeeze (PV); cough (anal canal and rectum maximum pressure, anal canal PV); push (anal canal and rectum maximum pressure). Anal canal relaxation was higher in women (push).ConclusionsLP reproducibility is feasible under water-perfused HRM, and comparative studies could bring similarity to dataset expansion. Novel 3D parameters need further studies with healthy and larger data to be validated and for disease comparisons.Key points• London Protocol and Classification allied with the technological evolution of HRM (software and probes) has refined the diagnostic armamentarium in anorectal disorders.• Novel 3D and deepening the analysis of manometric parameters before the London Classification as a contributory diagnostic tool.• Comparison of healthy volunteers according to the London Protocol under a perfusional high-resolution system could establish equivalence points.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.