Abstract

PurposeThe purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to determine normal alignment of the tibia in the coronal plane.Materials and MethodsThere are two parts to this study: in the first part, LCP PLT was applied to 30 cadaveric adult tibia. The angle between the joint line and the proximal most screw was measured and termed as the 'joint screw angle' (JSA). In the second part, 56 proximal tibial fractures treated with LCP PLT were retrospectively studied. Two angles were measured on the radiographs, the medial proximal tibial angle (MPTA) and the JSA. Their relationship was analyzed statistically.ResultsThe average JSA was 1.16 degrees in the anatomical study. Statistical analysis of the clinical study showed that the normal MPTA had a direct correlation with an acceptable JSA.ConclusionWe therefore conclude that the JSA can be used intraoperatively to assess the achievement of a normal coronal axis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.