Abstract

An improved method for ultrasonic location of multiple flaws using perpendicular ultrasonic arrays, working in near-field conditions, is presented. The method uses the pulse-echo technique and is based on the processing of the information acquired by both the elemental emitting transducers and their adjacent ones. This type of processing improves the performance of a previous method that sometimes presents limitations for the detection of multiples flaws. This new method is applied to a set of ultrasonic traces, obtained with an ultrasonic prototype specifically designed for testing this method, showing the improvement obtained in imaging results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call