Abstract
We demonstrate that scanning SQUID (Superconducting Quantum Interference Device) microscopy is a fast and easy method for finding the location of power-to-ground shorts in a series of chip-first MCM (multi-chip module) samples. Previous work has shown that the scanning SQUID microscope is capable of locating shorts in a C4 chip carrier and a ball grid array package, however the physical analysis was not performed to verify the (presumed) fail locations. In the present work, shorted areas in a chips-first MCM were located by SQUID microscopy and confirmed by mechanical cross-sectioning. When a short in a second MCM was found by SQUID microscopy and repaired with a laser, the power-to-ground resistance increased by more than a factor of 1000, bringing the part within specification. Techniques such as emission microscopy were unsuccessful in detecting the shorted current paths in these devices. Thus scanning SQUID microscopy is the only known method for locating and repairing defects in this product.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.