Abstract
This study reports a new mechanism of grain boundary (GB) sensitization without precipitation of Cr-rich phases at GBs in Cu-containing Ni-Cr-Fe alloys. Copper segregation at GBs during annealing can deplete the boundaries of Cr due to the repulsive interaction between Cr and Cu. The depletion of passivating Cr along GBs can cause intergranular corrosion susceptibility, as evidenced by electrochemical testing and post-mortem morphological characterization. The implications of this new sensitization mechanism on the localized corrosion resistance of Cu-containing commercial alloys are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.