Abstract
The presence of Pseudomonas fluorescens in artificial tap water (ATW) affects the composition of the oxide layer and the susceptibility to pitting corrosion of copper and 70/30 brass. The surface layer was investigated by means of a combination of electrochemical and spectroelectrochemical techniques involving cyclic voltammograms, potentiodynamic reduction curves, anodic polarisation curves, weight-loss tests and reflectance spectroscopy. In the sterile conditions the mass loss is lower in brass than in copper while the presence of bacteria enhances the attack in brass. Dezincification in inoculated electrolyte was revealed by microscopic observation, as well as by potentiodynamic reduction curves. Zn dissolution was also supported by spectroscopic evidence. Slow-rate voltamperometric curves were used to determine potential values characteristic of localized corrosion. In the presence of bacteria, the pitting potential moves towards more positive values for both materials but the difference between the repassivation and the pitting potential increases. Bigger and deeper pits can be seen in the presence of microorganisms.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.