Abstract

Abstract The aim of this paper is to localize the fugitive leaks from the above ground facilities of the existing system of Titas Gas (TG) after developing mathematical model for fugitive emission. Soap screening techniques and Gasurveyor 500 series instrument were used in this study for detecting potential leaks. Leaked gas was quantified using either Hi-Flow gas sampler or bagging measurements system. The results show that the respective potential gas leaking point of City Gate Station (CGS), commercial Regulating and Metering Station (RMS), industrial RMS, residential RMS and Town Bordering Station (TBS)/ District Regulating Station (DRS) are scrubber dump valve (average leak rate 217.00 L/min), insulating point (average leak rate 4.04 L/min), tube fitting connector (average leak rate 8.00 L/min), connector (average leak rate 1.55 L/min) and pressure relief valve (average leak rate 437.92 L/min). Fugitive methane emission can be reduced by stopping leaks of fittings or components having high KLeak value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.