The authors describe the localization and speech-understanding abilities of a patient fit with bilateral cochlear implants (CIs) for whom acoustic low-frequency hearing was preserved in both cochleae. Three signals were used in the localization experiments: low-pass, high-pass, and wideband noise. Speech understanding was assessed with the AzBio sentences presented in noise. Localization accuracy was best in the aided, bilateral acoustic hearing condition, and was poorer in both the bilateral CI condition and when the bilateral CIs were used in addition to bilateral low-frequency hearing. Speech understanding was best when low-frequency acoustic hearing was combined with at least one CI. The authors found that (1) for sound source localization in patients with bilateral CIs and bilateral hearing preservation, interaural level difference cues may dominate interaural time difference cues and (2) hearing-preservation surgery can be of benefit to patients fit with bilateral CIs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.