Abstract

AbstractThe local mass transfer rates from a submerged vertical jet parallel to the vertical electrode surface were measured by a limiting current density technique. For these studies, the parameters considered are a plate Reynolds number in the range of 1965 to 136500, electrode height over the orifice of the jet (Y) which varied from 0 to 12 times the jet orifice diameter (d), and the vertical distance of the microelectrode on the electrode plate in the range of 0.7 to 12.5 cm. The system used for measuring the limiting current was the reduction of copper ions. The relationship between the local Sherwood number (Sh) and Reynolds number (Re) was found to be Sh = 0.0004(Re)1.5 (Sc)0.33This relationship is valid for Y/d ≤ 6.0.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.