Abstract

To investigate the feasibility of local delivery of a magnetic resonance (MR) contrast agent in vivo using paramagnetic thermosensitive liposomes and infrared (IR) laser-induced local hyperthermia under real-time MR thermometry on rabbit kidney. Respiratory gated, radio frequency (RF)-spoiled gradient-echo sequences were used for precise MR temperature mapping (SD = 1 degrees C). In vivo heating experiments confirmed local release of MR contrast agent from liposomes. T1 decreased from 800 msec to about 500 msec, as measured after tissue cooling, in those locations where the renal parenchyma was heated above the phase transition temperature of the liposome membrane. The release of MR contrast agent has been demonstrated in rabbit kidney in vivo. This may be used as a reporter for simultaneous release of therapeutic agents.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.