Abstract

The local chemistry changes within the triple points of the Si 3N 4 based ceramics are discussed. The extents of Fe, Cr and Ti impurities segregation and coalescence after crystallization of the triple point were determined. These impurities were present also prior to crystallization in the glassy triple pockets but they were distributed over the whole volume of the triple pockets and were thus under the detection limits of the EDX method. The paper indicates that these coalesced impurities are responsible for cavity formation in the Si 3N 4 based composites studied.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.