Abstract

Measurements of the derivative of the microwave absorption coefficient as a function of static magnetic field H have been carried out in high-mobility (1.0\ifmmode\times\else\texttimes\fi{}${10}^{6}$ ${\mathrm{cm}}^{2}$/V sec) $n$-type lead telluride at 70 GHz and 4.2\ifmmode^\circ\else\textdegree\fi{}K. The measurements were taken in the Voigt (${\mathbf{q}}_{0}\ensuremath{\perp}\mathbf{H}$, where q0 is the incident radiation wave vector) and Faraday (${\mathbf{q}}_{0}\ensuremath{\parallel}\mathbf{H}$) configurations, as well as in intermediate geometries, where a mixed Voigt-Faraday situation applied. The sample surface, a {110} plane, was fixed perpendicular to q0, and H was rotated in a {100} plane which contained q0. The data were analyzed using well-known local theory and a simplified nonlocal theory for the Azbel-Kaner and Doppler-shifted cyclotron resonances. The observed local magneto-plasma effects agreed with those predicted from the $〈111〉$-ellipsoid model and included the hybrid resonance which has not been previously reported in lead telluride. The values deduced for the transverse mass ${m}_{t}$ and the mass ratio $K=\frac{{m}_{l}}{{m}_{t}}$ were $\frac{{m}_{t}}{{m}_{0}}=0.043\ifmmode\pm\else\textpm\fi{}0.04$ and $K=9.7\ifmmode\pm\else\textpm\fi{}1.4$ at a carrier concentration of 8.1\ifmmode\times\else\texttimes\fi{}${10}^{17}$ ${\mathrm{cm}}^{\ensuremath{-}3}$. Two weak, low-field resonances were identified as the first and second Azbel-Kaner subharmonics of a tilted-orbit cyclotron resonance. The values of the magnetic field at which the resonances and dielectric anomalies were observed in the Faraday geometry were shifted 4-19% relative to the corresponding values in the Voigt geometry, and some of these shifts agreed with the predictions of the simple Doppler-shift theory. Analysis of the Voigt dielectric-anomaly data gave a value of ${10}^{4}$ for the static part of the lattice dielectric constant. A similar value has been obtained in microwave-helicon experiments, while other methods of determination have given values near 400.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.