Abstract

The Villermaux-Dushman protocol with UV-Vis analytics is an established tool to characterize the global micro mixing performance in process equipment. The local mixing process is described by a micro mixing model (incorporation model), originally designed for turbulent flows. The novel imaging UV-Vis spectroscopy used in this work uncovers locally resolved micro mixing phenomena in a laminar split-and-recombine (SAR) mixer unit manufactured from selective laser-induced etching (SLE). The local absorbance is recorded with a high spatial resolution camera through a telecentric lens and post-processed into local concentration fields of components. The method unveils discrepancies of the micro mixing time determined from the conventional incorporation model in laminar flow and the locally recorded mixing process. The micro mixing time rather needs to be seen as a mean micro mixing time instead. Furthermore, the spatial information obtained by the imaging UV-Vis spectroscopy gives insight into local micro mixing and selectivity, yielding new approaches to equipment optimization.