The analyses presented pertain to loss of coolant accidents (LOCA), loss of coolant flow accidents (LOFA) and loss of vacuum accidents (LOVA). These types of accidents may jeopardise components and plasma vessel integrity and cause radioactivity mobilisation. The analyses reviewed have been performed under the assumption that the plasma facing components are protected by a carbon based armour. Accidental temperatures and pressure transients are quantified, the possibility of reaction products combustion is investigated and worst case accidental public doses are assessed. On this basis, design recommendations are given and design features such as low plasma facing components armour temperatures (on almost the entire surface) and inert gas adjacent to the vacuum vessel have been implemented.