Abstract

PurposeThe aim was to investigate the load bearing capacity of different pressable lithium disilicates cemented as occlusal veneers on molars. Materials and methodsOne control group and six test groups were formed consisting of 20 specimens each (n = 20). The six test groups differed in the utilizing pressable lithium disilicate to fabricate occlusal veneers. As a control group, “group Lis”, the lithium disilicate with the highest reported flexural strength was used (initial LiSi Press, GC Europe; Leuven, Belgium / flexural strength: 508 MPa). The test groups consisted of other pressable lithium disilicates with lower flexural strength values: “Ema” (IPS e.max press), “Vit” (VITA Ambria), “Liv” (Livento Press), “Amb” (Amber Press), “Mas” (Amber Press Master) and “Ros” (Rosetta SP)“. After the preparation of 140 extracted human molars, which included the removal of the central enamel, the specimens were scanned using a desktop scanner. With the aid of a design software, the occlusal veneers were designed in a standardized thickness of 0.5 mm. To fabricate the restorations, all tested materials were processed using heat-pressing technique. All restorations were adhesively cemented. Afterwards, the specimens underwent cyclic fatigue during an aging procedure in a chewing simulator (1’200’000 chewing-cycles, 49 N force, 5–55°C temperature changes). Subsequently, the specimens were statically loaded and the load which was necessary to fracture the specimen (Fmax) were measured. Differences between the groups were compared applying the Kruskal-Wallis (KW) test and the Wilcoxon-Mann-Whitney-Test (WMW: p < 0.05). The two-parameter Weibull distribution values were calculated. ResultsThe fatigue resistance was 100% for the groups Lis, Vit, Liv, Amb, Mas and Ros, whereas the group Ema showed a fatigue resistance of 95%. The control group Lis showed median Fmax values of 2’328 N. The median Fmax values for the test groups ranged between 1’753 N (Vit) and 2’490 N (Ros). Statistically significant difference was observed among the groups Lis (control) and Vit (KW: p < 0.001). Weibull distribution presented the highest shape values for the group Ros (12.83) and the lowest values for the group Ema (4.71). ConclusionRegarding their load-bearing capacity different pressable lithium disilicates can be recommended to fabricate ultra-thin occlusal veneers on molars when restoring occlusal tooth wear.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call