Abstract
To enable a better understanding of the load transfer performance of fully grouted cable bolts, a new laboratory short encapsulation pull test (LSEPT) unit has been designed and constructed. With this unit, both peak and residual capacity can be assessed over a relatively large pull-out displacement range of 100 mm. Various cable bolt failure modes, including relative slippage along the cable/grout and grout/rock interface, can be studied. Both a modified and a plain strand cable bolt confined in a material having a low strength of 8 MPa were tested. Within this testing process, the impact of the design of the bearing plate was considered that was found to alter the failure mode of the modified cable bolt. Other factors are considered, including the influence of borehole diameter, cable surface geometry, and sample strength on the axial performance of cable bolts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.