Abstract

As part of the design of an important pile foundation, an extensive testing program has been carried out in order to determine the type and the necessary characteristics of the pile best suited to the site and the structure to be designed. Three types of piles have been tested, i.e. timber piles, a steel H-pile, and a Herkules precast concrete pile. The Herkules and H-piles were equipped with deformation gauges and driven in 10-ft (3-m) increments to a total length of 70 ft (21 m), a loading test being carried out at the end of each increment. Thus, it was possible to determine the variations of the bearing capacity, the point–resistance, and the skin-friction as functions of the embedded pile length.The aim of this paper is to present the technique used and the results obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.