Abstract

To evaluate the remaining strength of a plain concrete arch bridge, dynamic and static load test was carried out. In the static test, up to 7300 kN of weight was applied, and in the dynamic test, a 1200 kN locomotive was used. The bridge demonstrated relatively stiff and strong response, despite initiation of enormous cracks, and it yielded under load levels much greater than the service load. The performance could be compared to a multi-layered continuous structure rather than to an arch form. The study showed that the bridge still enjoyed relatively large strength reserve and proper dynamic performance, despite deep and wide cracks, suffering from carbonation, and being more than 60-year old.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.