Abstract

A summary is given of reported trends in fatigue crack growth observed in variable amplitude fatigue tests on metallic materials, specifically on steels, under both simple and complex load histories. The effects of load variables, specimen geometry, material properties, microstructure and environment are considered. Attention is given to the threshold behaviour and small crack effects. The reviewed data suggest that, depending on a particular combination of load parameters, material, geometry and environment, variable amplitude load sequences of the same type can produce either retardation or acceleration in fatigue crack growth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.