Abstract
Based on 69 tests, recommendations are made for immediate revision o design standards and necessary additional research on timber connectors. he mean safety factor for four‐connector joints is alarmingly low at .88 for the first series of 34 specimens and increases to 1.21 for the 20 tests of he second series from a new shipment of billets. The mean safety factor for 5 three‐connector tests is 1.06. Tensile strengths perpendicular to the glueline re reported and compared with tests reported in 1975. The strength of the test aterial is about 1/3 to 1/2 of that expected. The low safety factors are attributed o a combination of the poor distribution of loads among connectors and he low perpendicular to glueline tensile strength. A finite element stress analysis n single connector joints is used to investigate the effect of varying end istances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.