Abstract
We present in this paper lightning current measurements, LMA (Lightning Mapping Array) data and fast antenna electric fields associated with upward flashes observed at the Säntis Tower during summer of 2017. The LMA network consists of six stations that were installed in the vicinity of the tower at distances ranging from 100 m to 11 km from it. Out of 20 LMA recorded flashes here we analyze in detail three so-called ‘other-triggered flashes’, triggered by preceding activity. Based on the lightning activity derived from the European Lightning Detection Network (EUCLID) in an area within 30 km from the tower and within a 1-s time window before the start of the upward tower flashes, only one out of 20 flashes was classified as ‘other-triggered’(OT). However, the investigations based on the LMA data reveal that 3 more flashes of the 20 analyzed were preceded by nearby activity and should therefore be classified as OT flashes. We analyze conditions conducive to the OT flashes, such as the charge structure of the clouds, polarity of preceding leaders and level of activity of the storm.The LMA source active time period was on average seven times higher for the OT flashes than that for self-initiated flashes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.