Abstract
To prospectively compare accuracy of dynamic contrast material-enhanced thin-section multi-detector row helical computed tomography (CT), high-spatial-resolution three-dimensional (3D) dynamic gadolinium-enhanced magnetic resonance (MR) imaging, and superparamagnetic iron oxide (SPIO)-enhanced MR imaging with optimized gradient-echo (GRE) sequence for depiction of hepatic lesions; surgery and histologic analysis were the reference standard. Local ethics committee approval was granted, and written informed consent was obtained. Fifty-eight patients (45 men, 13 women; age range, 47-82 years) with hepatic metastases were imaged with multi-detector row CT (3.2-mm section thickness), 3D dynamic gadolinium-enhanced MR imaging (2.5-mm effective section thickness), and SPIO-enhanced MR by using an optimized T2-weighted GRE sequence. Images were reviewed independently by two blinded observers who identified and localized lesions with a four-point confidence scale. Accuracy of each technique was measured with alternative free-response receiver operating characteristic analysis. Results were correlated with findings at surgery with intraoperative ultrasonography or histopathologic examination. Statistical differences among techniques for each observer were measured. Accuracy values for each observer for all metastases (n = 215) and 1.0-cm or smaller metastases (n = 80), respectively, follow: For CT, those for reader 1 were 0.82 and 0.65; for reader 2, 0.81 and 0.68. For gadolinium-enhanced MR imaging, those for reader 1 were 0.92 and 0.79; for reader 2, 0.90 and 0.76. For SPIO-enhanced MR imaging, those for reader 1 were 0.92 and 0.83; for reader 2, 0.92 and 0.81. For all metastases for both observers, there was no significant difference between MR techniques, but both were significantly more accurate than CT (P < .01). For metastases 1.0 cm or smaller and one observer, there was no significant difference between MR techniques, but both were more accurate than CT (P < .01); for the other observer, SPIO-enhanced MR imaging was more accurate than gadolinium-enhanced MR imaging (P < .05) and CT (P < .02), but there was no significant difference between gadolinium-enhanced MR imaging and CT (P = .2). Accuracy for gadolinium-enhanced MR imaging and SPIO-enhanced MR imaging was similar. Both techniques were significantly more accurate than CT.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.