Abstract
The purpose of this HIPAA-compliant, institutional review board-approved study was to assess the liver and spleen volumes calculated by using a semiautomated dual-space clustering segmentation technique, as compared with the volumes calculated by using the manual contour-tracing method. The quantitative magnetic resonance (MR) imaging data used as input were computed from images acquired by using a mixed fast spin-echo pulse sequence that was implemented with respiratory triggering. Linear regression analysis was used to assess agreement regarding the volumes calculated by using both segmentation techniques. There was strong agreement regarding the regression parameters for the liver (r = 0.98, P < .001) and the spleen (r = 0.99, P < .001) and the mean percentage volume differences for the liver (1.2%) and the spleen (0.9%). The mean segmentation time per patient was significantly shorter with use of the dual-space clustering method (P < .001).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.