Abstract

Light-sheet fluorescence microscopy (LSFM), a prominent fluorescence microscopy technique, offers enhanced temporal resolution for imaging biological samples in four dimensions (4D; x, y, z, time). Some of the most recent implementations, including inverted selective plane illumination microscopy (iSPIM) and lattice light-sheet microscopy (LLSM), move the sample substrate at an oblique angle relative to the detection objective's optical axis. Data from such tilted-sample-scan LSFMs require subsequent deskewing and rotation for proper visualisation and analysis. Such data preprocessing operations currently demand substantial memory allocation and pose significant computational challenges for large 4D dataset. The consequence is prolonged data preprocessing time compared to data acquisition time, which limits the ability for live-viewing the data as it is being captured by the microscope. To enable the fast preprocessing of large light-sheet microscopy datasets without significant hardware demand, we have developed WH-Transform, a memory-efficient transformation algorithm for deskewing and rotating the raw dataset, significantly reducing memory usage and the run time by more than 10-fold for large image stacks. Benchmarked against the conventional method and existing software, our approach demonstrates linear runtime compared to the cubic and quadratic runtime of the other approaches. Preprocessing a raw 3D volume of 2 GB (512 × 1536 × 600 pixels) can be accomplished in 3 s using a GPU with 24 GB of memory on a single workstation. Applied to 4D LLSM datasets of human hepatocytes, lung organoid tissue and brain organoid tissue, our method provided rapid and accurate preprocessing within seconds. Importantly, such preprocessing speeds now allow visualisation of the raw microscope data stream in real time, significantly improving the usability of LLSM in biology. In summary, this advancement holds transformative potential for light-sheet microscopy, enabling real-time, on-the-fly data preprocessing, visualisation, and analysis on standard workstations, thereby revolutionising biological imaging applications for LLSM and similar microscopes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.