Abstract

AbstractThe Kettle River Bridge is an arched, steel cantilevered deck, Pratt Truss bridge. To quantify the live-load performance of the bridge superstructure and provide a baseline for future comparisons, it was instrumented with 151 strain gauges on various beam, stringer, and truss members. In addition, 8 displacement gauges were attached along the truss. All gauges were simultaneously monitored while the bridge was subjected to a nondestructive, live-load test. The recorded bridge response was analyzed to quantify in situ behavior. The measured behavior was then used to validate a finite-element model using solid and frame elements, which was subsequently used to obtain an inventory- and operating-load rating of 2.03 and 2.64, respectively. Based on the results of the test, it was concluded that the large gusset plates added partial fixity to the truss members, as evident from the significant measured in-plane bending strains. However, the beam-and-stringer deck support system showed minimal rotational...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.