Abstract
Liquisolid pellets (LPs) prepared by extrusion-spheronization are promising delivery systems to improve the dissolution rate of poorly water-soluble drugs. However, developing LPs for high dose drugs (e.g. antiretroviral ritonavir, RTV) is a major challenge due to technical and quality constraints. In this study, formulations LP1 and LP2 were obtained (RTV 100 mg/unit dose) using microcrystalline cellulose (carrier), Kollidon® CL-SF (coating and disintegrating material) and high load (30%, w/w) of Kolliphor® EL or PEG 400 (non-volatile solvent). LP1 and LP2 had narrow size distribution, good morphological properties, and excellent flowability. The partial conversion of RTV polymorph I to the less soluble form II occurred during the preparation of the liquid medications. LP1 (containing Kolliphor® EL) achieved 82.64 ± 2.17% of drug dissolved in 30 min (Q30min), compared with 53.14 ± 0.6% and 42.42 ± 2.09% for LP2 (containing PEG 400) and Norvir® tablets, respectively. Also, LP1 promoted 1.9-fold/1.7-fold and 8.19-fold/8.29-fold increases in Q30min/DE60min (dissolution efficiency) as compared to neat RTV polymorphs I and II, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.