Abstract

We evaluated the safety and efficacy of partial liquid ventilation in a series of 19 adults, children, and neonates who were in respiratory failure and on extracorporeal life support. During partial liquid ventilation, the alveolar-arterial oxygen difference decreased from 590 (SE 25) to 471 (42) mm Hg (p=0·0002) and static pulmonary compliance increased from 0·18 (0·04) to 0·29 (0·04) mL cm H2O-1 kg-1 (p=0·0002). 11 patients (58%) survived. These preliminary data suggest that partial liquid ventilation can be safely used in patients with severe respiratory failure and may improve lung function.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.