Abstract
Liquid entrainment rate and drop size distribution were measured in the exhaust gas stream from a mobile bed scrubber. The pilot plant scrubber was 46 cm (18 in.) square and was packed with 3.8 cm (1.5 In.) diameter hollow polyethylene spheres to a static depth of 25 cm (10 in.). Entrainment flow rate depends on both gas and liquid rates. At a liquid/gas ratio of 6.7 l/m3 (50 gal/Mcf) and a superficial gas velocity of 2.6 m/sec (8.5 ft/sec) the entrainment flow rate was 0.0064 l/m3 (0.05 gal/Mcf) and at 3.75 m/sec (12.3 ft/sec) it was 0.031 l/m3 (0.23 gal/Mcf). The mass median drop diameter was about 400 nm at a liquid/gas ratio of 6.7 l/m3. The drop size distribution appears to be bimodal. Dye impregnated paper and cascade impactor techniques were used to measure drop size.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.