Abstract

The measurement of steroid hormones provided critical information in the clinical evaluation of endocrine disorders. In this study, we developed a high-throughput solid-phase extraction method for the analysis of 26 steroids in human serum and plasma samples by liquid chromatography-tandem mass spectrometry. Chromatographic conditions and sample preparation were optimized to achieve good separation and maximum sensitivity for these analytes. Under the optimum conditions, good linearities were achieved in the quantitative range for each steroid hormone with the correlation coefficients (r) larger than 0.99. The limits of quantitation of the method were in the range from 0.0005 to 0.7901ng/mL. The recoveries were in the range of 87.2-114.2% with intra- and interday precision lower than 9.94%. This method has already been applied to series of samples from clinical trials, and there was no significant difference between serum and ethylenediaminetetraacetic acid plasma samples.