Abstract

A method for the simultaneous determination of quinolones in water and urine samples by microextraction in a sorbent-packed syringe (MEPS) with LC is described. MEPS is a new miniaturized SPE technique that can be used with chromatographic instruments without any modifications. In MEPS, approximately 1 mg of the solid packing material is inserted into a syringe (100-250 microL) as a plug. Sample preparation takes place on the packed bed. The new method is promising, easy to use, economical, and rapid. The determination of quinolones in groundwater and urine was performed using MEPS as a sample preparation method with LC-UV determination. Four quinolone antibiotics--enrofloxacin, enoxacin, danofloxacin, and nalidixic acid--in groundwater and urine samples were used as analytes. The extraction recovery was found to be between 64.9 and 98.9%. The results showed high correlation coefficients (R2 > 0.992) for all of the analytes within the calibration range. The LOQ was between 0.091 and 0.315 ng/mL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.