Abstract

Porous filters and collodion film impregnated with decane solution of phospholipids, were used for measurements of electric potential differences generated by bacteriorhodopsin, chromatophore redox chain, H +-ATPase, pyrophosphatase, and mitochondrial respiratory chain. It was shown that reconstituted proteoliposomes, containing e.g., bacteriorhodopsin or natural coupling membrane vesicles, such as Rhodospirillum rubrum chromatophores, can be attached to a filter surface by means of Ca 2+ or Mg 2+ ions. Addition of the respective energy source was found to result in electric potential difference being generated across the filter. This effect was measured directly by Ag AgCl electrodes immersed into electrolyte solutions on both sides of the filter. Using a phospholipid-impregnated collodion film one can measure electric responses as fast as 300 nsec. The phospholipid-impregnated filters turned out to be sensitive and reliable electrodes for measuring the concentration of synthetic penetrating ions, such as phenyldicarbaundecaborane, tetraphenylborate, tetrapentylammonium, and tetraphenylphosphonium. By measuring changes in the concentration of these ions in the suspension of proteoliposomes, chromatophores, mitochondria, or bacterial cells, one can follow the formation and dissipation of transmembrane potential differences in these systems. It is shown that the phospholipid-impregnated filters are much more reliable and handy than planar phospholipid membranes previously used for studying electrogenic activity of electric current-producing membrane proteins.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call