Abstract

A linear scanning system utilizing constant wave 280 GHz radiation has been developed and characterized. The system comprises a linear array of detectors based on a unique plasma wave approach in terahertz sensing, an impact ionization avalanche transit-time-diode signal generator coupled to a frequency multiplier and an optical system. The performed tests allowed us to estimate the resolution of the system reaching the value of 2.3 mm and to determine the dynamic range of the system to be around 200. The imaging capabilities of the scanner were tested in realistic cases of non-destructive testing and security screening.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.