Abstract

Problem statement: This study highlights on restoration scheme proposed against failure in working line at the drop region for Fiber-To-The Home (FTTH) with a Passive Optical Network (PON). Whereas PON is a system that brings optical fiber cable and signals all or most of the way to the end user. Approach: Survivability scheme against failure is focused on scattered residence architectures and it is applied in the ring and tree topology respectively by means of Customer Access Protection Unit (CAPU). CAPU will be installed before the ONU and ensure the signal will find the alternative path when failure occurs at the specific line. Our proposal scheme is low cost and applicable to any residence architecture. The advantage of this scheme is the failure at fiber line can be recovered until three levels to make sure the optic signal flow continuously to avoid any application disturbance. Two type of restoration scheme is proposed by means of linear protection (tree) and migrated protection (ring). FTTH based network design is simulated by using Opti System 7.0 in order to investigate the power output and BER performance at each node in the tree and ring protection scheme in scattered placement. This study we perform an analysis on linear protection scheme that consisting of two model a) Line to Line (L2L) protection and CAPU to CAPU (C2C) or Shared protection. However the migration of tree to ring topology to enable the signal flow continuously in the case of failure occurs specifically in random or scattered placement topology has been highlighted in our previous publication. Results: The signal will be divided into section; drop and pass through and the ratio is significant to determine the number of user allowed and achievable distance. Output power for optical nodes could be slightly improved by varying the pass through and drop signal ratio. Conclusion: Our proposal is the first reported up to this time in which the upstream signal flows in anticlockwise in ring topology when the restoration scheme activated.

Highlights

  • Survivability in FTTH network is an important issue. It has been discussed in optical network by earlier studies

  • The signal can choose one line to go through the Optical Network Unit (ONU) when the failure is occur in the other line (Han et al, 2007)

  • The linear protection signal is separate by splitter and the power dropped it not occur at each optical node

Read more

Summary

Introduction

Survivability in FTTH network is an important issue. It has been discussed in optical network by earlier studies. The linear protection signal is separate by splitter and the power dropped it not occur at each optical node. Before reaching to the ONU, Fig. 1: Two restoration schemes are proposed and be activated according to PON (a) Zero Fault Condition (b) Linear Protection (c) Migrated Protection optical signal must passing and will be divided according to percentage in every node optic.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.