Abstract

The applicability of employing a parameter-dependent control to a nuclear pressurized water reactor is investigated and is compared to that of using an ℋ︁∞ control. A linear time-invariant controller cannot maintain performance over the entire operating range. The parameter-dependent synthesis technique produces a controller which achieves specified performance against the worst-case time variation of a measurable parameter which enters the plant in a linear fractional manner. The plant can thus have widely varying dynamics over the operating range. The controllers designed perform well over the entire operating range. Copyright © 1999 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.