Abstract
Abstract This paper describes a new2 nd generation linear focus solar simulator test bench. The test bench is used for the non-destructive calorimetric measurement of relative optical efficiency of parabolic trough receivers. Compared to the predecessor, the test bench has been optimized for faster measurement, better long term stability and easier operation. The test bench optics is an elliptical shaped glass mirror trough with flat end mirrors. The receiver and six solar simulator lamps, metal halide lamps with 2.5 kWeeach are located in their respective focal lines. Absorbed power is measured via temperature increase of the water flowing through the receiver and the mass flow rate. By comparison to the absorbed power of a reference receiver, the optical efficiency of a sample can be determined relative to the optical efficiency of the reference receiver.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.