Abstract

To develop limited sampling strategies for estimation of mycophenolic acid exposure (by determining area under the concentration-time curve [AUC]) in lung transplant recipients by using sampling times within 2 hours after drug administration and a maximum of three plasma samples. Prospective, open-label clinical study. Lung transplant clinic in Vancouver, British Columbia, Canada. Nineteen adult (mean age 48.3 yrs) lung transplant recipients who were receiving mycophenolate mofetil therapy along with cyclosporine (9 patients) or tacrolimus (10 patients). Eleven blood samples were collected from each of the 19 patients over 12 hours: immediately before (0 hr) and 0.3, 0.6, 1, 1.5, 2, 4, 6, 8, 10, and 12 hours after administration of mycophenolate mofetil. Mycophenolic acid levels in plasma were determined by a high-performance liquid chromatography-ultraviolet detection method. The 19 patients were randomly divided into index (10 patients) and validation (9 patients) groups. Limited sampling strategies were developed with multiple regression analysis by using data from the index group. Data from the validation group were used to test each strategy. Bias and precision of each limited sampling strategy were determined by calculating the mean prediction error and the root mean square error, respectively. The correlation between AUC and single concentrations was generally poor (r2= 0.18-0.73). Two single-concentration strategies, eight two-concentration strategies, and eight three-concentration strategies matched our criteria. However, the best overall limited sampling strategies (and their predictive performance) were the following: log AUC = 0.241 log C0 + 0.406 log C2 + 1.140 (bias -5.82%, precision 5.97%, r2= 0.828) and log AUC = 0.202 log C0 + 0.411 log C1.5 + 1.09 (bias -5.71%, precision 6.94%, r2= 0.791), where Cx is mycophenolic acid concentration at time x hours. Two-concentration limited sampling strategies provided minimally biased and highly precise estimation of mycophenolic acid AUC in lung transplant recipients. These optimal and most clinically feasible limited sampling strategies are based collectively on the number of blood samples required, r2 value, bias, and precision.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.